115-11-7 structure, C4H8

Isobutene

CAS No.

115-11-7

Formula:

C4H8

Basic Info

Isobutylene (or 2-methylpropene) is a hydrocarbon of industrial significance. It is a four-carbon branched alkene (olefin), one of the four isomers of butylene. At standard temperature and pressure it is a colorless flammable gas.

Formula
C4H8
Molecular Weight
56.1063
Exact Mass
56.0626
LogP
1.5824
PSA
0
Synonyms

Methylpropene

1-Propene,2-methyl

1-PROPENE, 2-METHYL-

2-Methyl-1-propene

2-Methylpropene

ISOBUTENE

ISOBUTYLENE

Propene,2-methyl

2-methylprop-1-ene

2-Methylpropylene

expand collapse

Properties

Appearance & Physical State
COLOURLESS COMPRESSED LIQUEFIED GAS , WITH CHARACTERISTIC ODOUR.
Density
0.627 g/cm3
Boiling Point
-6.9ºC(lit.)
Melting Point
-140ºC
Freezing Point
-140.34℃
Flash Point
-80ºC
Refractive Index
1.3811
Stability
Stable. Highly flammable - readily forms an explosive mixture with air. Incompatible with strong oxidizing agents.
Vapor Density
2 (vs air)
Vapor Pressure
3278 mm Hg ( 37.7 °C)

Safety Info

RTECS
UD0890000
Safety Statements
S9-S16-S33
WGK Germany
-
Risk Statements
R12
HS Code
2901233000
RIDADR
UN 1055
Hazard Class
2.1
Hazard Codes

MSDS

SDS 1.0
expand collapse
Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 10, 2017

Revision Date: Aug 10, 2017

1.Identification

1.1 GHS Product identifier

Product name Isobutene

1.2 Other means of identification

Product number -
Other names Propene,2-methyl

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only. Adhesives and sealant chemicals,Fuels and fuel additives,Intermediates,Lubricants and lubricant additives,Solvents (which become part of product formulation or mixture)
Uses advised against no data available

1.4 Supplier's details

Company MOLBASE (Shanghai) Biotechnology Co., Ltd.
Address Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road,
Xuhui District, Shanghai, China
Telephone +86(21)64956998
Fax +86(21)54365166

1.5 Emergency phone number

Emergency phone number +86-400-6021-666
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Gases under pressure: Compressed gas

Flammable gases, Category 1

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Danger

Hazard statement(s)

H220 Extremely flammable gas

Precautionary statement(s)
Prevention

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Response

P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.

P381 In case of leakage, eliminate all ignition sources.

Storage

P410+P403 Protect from sunlight. Store in a well-ventilated place.

P403 Store in a well-ventilated place.

Disposal

none

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
Isobutene Isobutene 115-11-7 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

Fresh air, rest. Artificial respiration may be needed. Refer for medical attention.

In case of skin contact

ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .

In case of eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

Inhalation of moderate concentrations causes dizziness, drowsiness, and unconsciousness. Contact with eyes or skin may cause irritation; the liquid may cause frostbite. (USCG, 1999)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Basic Treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... Anticipate seizures and treat as necessary ... For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... Do not use emetics. For ingestion, rinse mouth and administer 5 mL/kg up to 200 mL of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool. Administer activated charcoal ... Treat frostbite with rapid rewarming techniques ... /Aliphatic hydrocarbons and related compounds/

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

To fight fire, stop flow of gas.

5.2 Specific hazards arising from the chemical

Behavior in Fire: Containers may explode in fire. Vapor is heavier than air and may travel a long distance to a source of ignition and flash back. (USCG, 1999)

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Evacuate danger area! Consult an expert! Ventilation. Remove all ignition sources. Do NOT wash away into sewer. NEVER direct water jet on liquid. Personal protection: chemical protection suit including self-contained breathing apparatus.

6.3 Methods and materials for containment and cleaning up

Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Fireproof. Separated from incompatible materials. See Chemical Dangers. Cool.... MATERIALS WHICH ARE TOXIC AS STORED OR WHICH CAN DECOMPOSE INTO TOXIC COMPONENTS ... SHOULD BE STORED IN A COOL, WELL VENTILATED PLACE, OUT OF THE DIRECT RAYS OF THE SUN, AWAY FROM AREAS OF HIGH FIRE HAZARD, AND SHOULD BE PERIODICALLY INSPECTED. INCOMPATIBLE MATERIALS SHOULD BE ISOLATED ...

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state COLOURLESS COMPRESSED LIQUEFIED GAS , WITH CHARACTERISTIC ODOUR.
Colour Easily liquefied gas
Odour Coal gas odor
Melting point/ freezing point 204°C(lit.)
Boiling point or initial boiling point and boiling range 164°C/7mmHg(lit.)
Flammability Extremely flammable.
Lower and upper explosion limit / flammability limit no data available
Flash point 101°C(lit.)
Auto-ignition temperature 465°C (USCG, 1999)
Decomposition temperature no data available
pH no data available
Kinematic viscosity no data available
Solubility Insoluble
Partition coefficient n-octanol/water (log value) log Kow = 2.34
Vapour pressure 3278 mm Hg ( 37.7 °C)
Density and/or relative density 0.627 g/cm3
Relative vapour density 2 (vs air)
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

VOLATILE LIQUID OR EASILY LIQUEFIED GAS.

10.3 Possibility of hazardous reactions

A very dangerous fire and explosion hazard when exposed to heat or flame.The gas is heavier than air and may travel along the ground; distant ignition possible. The gas is heavier than air and may accumulate in lowered spaces causing a deficiency of oxygen. As a result of flow, agitation, etc., electrostatic charges can be generated.ISOBUTYLENE is incompatible with oxidizers. It polymerizes easily. It reacts easily with numerous materials, such as alkyl halides, halogens, concentrated sulfuric acid, hypochlorous acid, aluminum chloride, carbon monoxide and hydrogen with a cobalt catalyst. Polymerization is catalyzed by aluminum chloride and boron trifluoride.

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

CAN REACT VIGOROUSLY WITH OXIDIZING MATERIALS.

10.6 Hazardous decomposition products

When heated to decomposition it emits acrid smoke and fumes.

11.Toxicological information

Acute toxicity

  • Oral: LC50 Mouse oral 415 mg/L/2 hr
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

Isobutylene was degraded to 1,2-epoxybutane by pure cultures of methanotrophic bacteria(1).

12.3 Bioaccumulative potential

An estimated BCF of 35 was calculated for isobutylene(SRC), using a log Kow of 2.34(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is moderate(SRC).

12.4 Mobility in soil

The Koc of isobutylene is estimated as 450(SRC), using a log Kow of 2.34(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that isobutylene is expected to have moderate mobility in soil(SRC).

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN1993 IMDG: UN1993 IATA: UN1993

14.2 UN Proper Shipping Name

ADR/RID: FLAMMABLE LIQUID, N.O.S.
IMDG: FLAMMABLE LIQUID, N.O.S.
IATA: FLAMMABLE LIQUID, N.O.S.

14.3 Transport hazard class(es)

ADR/RID: 3 IMDG: 3 IATA: 3

14.4 Packing group, if applicable

ADR/RID: II IMDG: II IATA: II

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
Isobutene Isobutene 115-11-7 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 10, 2017
Revision Date Aug 10, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
MSDS
expand collapse

SECTION 1: Identification of the substance/mixture and of the company/undertaking
  Product identifiers
    Product name        : 2-Methylpropene    
    REACH No.        : A registration number is not available for this substance as the substance    
    or its uses are exempted from registration, the annual tonnage does not
    require a registration or the registration is envisaged for a later
    registration deadline.
    CAS-No.        : 115-11-7    
  Relevant identified uses of the substance or mixture and uses advised against
    Identified uses        : Laboratory chemicals, Manufacture of substances    
  
  

SECTION 2: Hazards identification
  Classification of the substance or mixture
  Classification according to Regulation (EC) No 1272/2008
    Flammable gases (Category 1), H220
    Gases under pressure (Liquefied gas), H280
    For the full text of the H-Statements mentioned in this Section, see Section 16.
  Classification according to EU Directives 67/548/EEC or 1999/45/EC
    F+ Extremely flammable        R12    
    For the full text of the R-phrases mentioned in this Section, see Section 16.
  Label elements
  Labelling according Regulation (EC) No 1272/2008
    Pictogram
    Signal word        Danger    
    Hazard statement(s)
    H220        Extremely flammable gas.    
    H280        Contains gas under pressure; may explode if heated.    
    Precautionary statement(s)
    P210        Keep away from heat/sparks/open flames/hot surfaces. - No smoking.    
    P410 + P403        Protect from sunlight. Store in a well-ventilated place.    
    Supplemental Hazard        none    
    Statements
  Other hazards - none

SECTION 3: Composition/information on ingredients
  Substances
    Synonyms        : Isobutylene    
    Formula        : C4H8    
    Molecular Weight        : 56,11 g/mol    
    CAS-No.        : 115-11-7    
    EC-No.        : 204-066-3    
    Index-No.        : 601-012-00-4    
    No components need to be disclosed according to the applicable regulations.
    For the full text of the H-Statements and R-Phrases mentioned in this Section, see Section 16

SECTION 4: First aid measures
  Description of first aid measures
  General advice
    Consult a physician. Show this safety data sheet to the doctor in attendance.
  If inhaled
    If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
  In case of skin contact
    Wash off with soap and plenty of water. Consult a physician.
  In case of eye contact
    Flush eyes with water as a precaution.
  If swallowed
    Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with
    water. Consult a physician.
  Most important symptoms and effects, both acute and delayed
    The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
    section 11
  Indication of any immediate medical attention and special treatment needed
    no data available

SECTION 5: Firefighting measures
  Extinguishing media
  Suitable extinguishing media
    Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
  Special hazards arising from the substance or mixture
    Carbon oxides
  Advice for firefighters
    Wear self contained breathing apparatus for fire fighting if necessary.
  Further information
    Use water spray to cool unopened containers.

SECTION 6: Accidental release measures
  Personal precautions, protective equipment and emergency procedures
    Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition.
    Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations.
    Vapours can accumulate in low areas.
    For personal protection see section 8.
  Environmental precautions
    Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
  Methods and materials for containment and cleaning up
    Clean up promptly by sweeping or vacuum.
  Reference to other sections
    For disposal see section 13.

SECTION 7: Handling and storage
  Precautions for safe handling
    Avoid inhalation of vapour or mist.
    Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic
    charge.
    For precautions see section 2.2.
  Conditions for safe storage, including any incompatibilities
    Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
  Specific end use(s)
    Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

SECTION 8: Exposure controls/personal protection
  Control parameters
  Components with workplace control parameters
  Exposure controls
  Appropriate engineering controls
    Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
    at the end of workday.
  Personal protective equipment
  Eye/face protection
    Face shield and safety glasses Use equipment for eye protection tested and approved under
    appropriate government standards such as NIOSH (US) or EN 166(EU).
  Skin protection
    Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
    (without touching glove's outer surface) to avoid skin contact with this product. Dispose of
    contaminated gloves after use in accordance with applicable laws and good laboratory practices.
    Wash and dry hands.
    The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
    the standard EN 374 derived from it.
    Full contact
    Material: Fluorinated rubber
    Minimum layer thickness: 0,7 mm
    Break through time: 480 min
    Material tested:Vitoject® (KCL 890 / Z677698, Size M)
    Splash contact
    Material: Nitrile rubber
    Minimum layer thickness: 0,4 mm
    Break through time: 60 min
    Material tested:Camatril® (KCL 730 / Z677442, Size M)
    data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300,     test method: EN374
    If used in solution, or mixed with other substances, and under conditions which differ from EN 374,
    contact the supplier of the CE approved gloves. This recommendation is advisory only and must
    be evaluated by an industrial hygienist and safety officer familiar with the specific situation of
    anticipated use by our customers. It should not be construed as offering an approval for any
    specific use scenario.
  Body Protection
    impervious clothing, Flame retardant antistatic protective clothing, The type of protective
    equipment must be selected according to the concentration and amount of the dangerous
    substance at the specific workplace.
  Respiratory protection
    Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator
    with multi-purpose combination (US) or type AXBEK (EN 14387) respirator cartridges as a backup
    to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air
    respirator. Use respirators and components tested and approved under appropriate government
    standards such as NIOSH (US) or CEN (EU).
  Control of environmental exposure
    Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

SECTION 9: Physical and chemical properties
  Information on basic physical and chemical properties
    a) Appearance        Form: Liquefied gas    
    b) Odour        unpleasant    
    c) Odour Threshold        no data available    
    d) pH        no data available    
    e) Melting point/freezing        Melting point/range: -140 °C    
    point
    f) Initial boiling point and -6,9 °C - lit.
    boiling range
    g) Flash point        -80 °C - closed cup    
    h) Evapouration rate        no data available    
    i) Flammability (solid, gas) no data available
    j) Upper/lower        Upper explosion limit: 9,6 %(V)    
    flammability or        Lower explosion limit: 1,8 %(V)    
    explosive limits
    k) Vapour pressure        4.370 hPa at 37,7 °C    
    l) Vapour density        2,25    
    m) Relative density        no data available    
    n) Water solubility        no data available    
    o) Partition coefficient: n- log Pow: 2,34
    octanol/water
    p) Auto-ignition        no data available    
    temperature
    q) Decomposition        no data available    
    temperature
    r) Viscosity        no data available    
    s) Explosive properties        no data available    
    t) Oxidizing properties        no data available    
  Other safety information
    Relative vapour density 2,25

SECTION 10: Stability and reactivity
  Reactivity
    no data available
  Chemical stability
    Stable under recommended storage conditions.
  Possibility of hazardous reactions
    no data available
  Conditions to avoid
    Heat, flames and sparks. Extremes of temperature and direct sunlight.
  Incompatible materials
    Strong oxidizing agents, Strong acids, Halogens
  Hazardous decomposition products
    Other decomposition products - no data available
    In the event of fire: see section 5

SECTION 11: Toxicological information
  Information on toxicological effects
  Acute toxicity
    LC50 Inhalation - rat - 4 h - 620.000 mg/m3
  Skin corrosion/irritation
    no data available
  Serious eye damage/eye irritation
    no data available
  Respiratory or skin sensitisation
    no data available
  Germ cell mutagenicity
    no data available
  Carcinogenicity
    IARC:        No component of this product present at levels greater than or equal to 0.1% is identified as    
    probable, possible or confirmed human carcinogen by IARC.
  Reproductive toxicity
    no data available
  Specific target organ toxicity - single exposure
    no data available
  Specific target organ toxicity - repeated exposure
    no data available
  Aspiration hazard
    no data available
  Additional Information
    RTECS: UD0890000
    Acts as a simple asphyxiant by displacing air., Dizziness, Disorientation, Headache, excitement, Central
    nervous system depression, To the best of our knowledge, the chemical, physical, and toxicological
    properties have not been thoroughly investigated.

SECTION 12: Ecological information
  Toxicity
    no data available
  Persistence and degradability
    no data available
  Bioaccumulative potential
    no data available
  Mobility in soil
    no data available
  Results of PBT and vPvB assessment
    PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
  Other adverse effects
    no data available

SECTION 13: Disposal considerations
  Waste treatment methods
  Product
    Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting
    as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal
    company.
  Contaminated packaging
    Dispose of as unused product.

SECTION 14: Transport information
  UN number
    ADR/RID: 1055        IMDG: 1055        IATA: 1055    
  UN proper shipping name
    ADR/RID: ISOBUTYLENE
    IMDG: ISOBUTYLENE
    IATA:        Isobutylene    
    Passenger Aircraft: Not permitted for transport
  Transport hazard class(es)
    ADR/RID: 2.1        IMDG: 2.1        IATA: 2.1    
  Packaging group
    ADR/RID: -        IMDG: -        IATA: -    
  Environmental hazards
    ADR/RID: no        IMDG Marine pollutant: no        IATA: no    
  Special precautions for user
    no data available

SECTION 15: Regulatory information
    This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
  Safety, health and environmental regulations/legislation specific for the substance or mixture
    no data available
  Chemical Safety Assessment
    For this product a chemical safety assessment was not carried out

SECTION 16: Other information
  Full text of H-Statements referred to under sections 2 and 3.
    H220        Extremely flammable gas.    
    H280        Contains gas under pressure; may explode if heated.    
  Full text of R-phrases referred to under sections 2 and 3
    R12 Extremely flammable.
  Further information
    Copyright 2014 Co. LLC. License granted to make unlimited paper copies for internal use
    only.
    The above information is believed to be correct but does not purport to be all inclusive and shall be
    used only as a guide. The information in this document is based on the present state of our knowledge
    and is applicable to the product with regard to appropriate safety precautions. It does not represent any
    guarantee of the properties of the product. Corporation and its Affiliates shall not be held
    liable for any damage resulting from handling or from contact with the above product. See
     and/or the reverse side of invoice or packing slip for additional terms and conditions of sale.

Spectrum

NMR Spectrum 1H NMR : Predict
expand collapse

Analysis Methods

Kovats' RI, non-polar column, isothermal
expand collapse
Column Shape
Capillary
Active Phase(℃)
BPX-5
Retention index
394.
Temperature Control
30.
Method
isothermal
Comments
12. m/0.15 mm/0.25 μm, H2
Reference
Aflalaye, A.Sternberg, R.Raulin, F.Vidal-Madjar, C.Gas chromatography of Titan's atmosphere. VI. Analysis of low-molecular-mass hydrocarbons and nitriles with BPX5 capillary columnsJ. Chromatogr. A1995, 708, 2, 283-291.
Kovats' RI, non-polar column, isothermal
expand collapse
Column Shape
Capillary
Active Phase(℃)
CP Sil 5 CB
Retention index
391.
Temperature Control
20.
Method
isothermal
Comments
25. m/0.15 mm/2. μm, H2
Reference
Do, L.Raulin, F.Gas chromatography of Titan's atmosphere. III. Analysis of low-molecular-weight hydrocarbons and nitriles with a CP-Sil-5 CB WCOT capillary columnJ. Chromatogr.1992, 591, 1-2, 297-301.
Kovats' RI, non-polar column, isothermal
expand collapse
Column Shape
Capillary
Active Phase(℃)
PoraPLOT Q
Retention index
389.
Temperature Control
100.
Method
isothermal
Comments
10. m/0.32 mm/10. μm, H2
Reference
Do, L.Raulin, F.Gas chromatography of Titan's atmosphere. I. Analysis of low-molecular-weight hydrocarbons and nitriles with a PoraPLOT Q porous polymer coated open-tubular capillary columnJ. Chromatogr.1989, 481, 45-54.
Kovats' RI, non-polar column, isothermal
expand collapse
Column Shape
Capillary
Active Phase(℃)
PoraPLOT Q
Retention index
390.
Temperature Control
160.
Method
isothermal
Comments
10. m/0.32 mm/10. μm, H2
Reference
Do, L.Raulin, F.Gas chromatography of Titan's atmosphere. I. Analysis of low-molecular-weight hydrocarbons and nitriles with a PoraPLOT Q porous polymer coated open-tubular capillary columnJ. Chromatogr.1989, 481, 45-54.
Kovats' RI, non-polar column, isothermal
expand collapse
Column Shape
Capillary
Active Phase(℃)
HP-PONA
Retention index
390.
Temperature Control
40.
Method
isothermal
Comments
50. m/0.21 mm/0.5 μm, H2
Reference
Lubeck, A.J.Sutton, D.L.Kovats Retention Indices of Selected Olefins on Bonded Phase Fused Silica CapillariesJ. Hi. Res. Chromatogr. Chromatogr. Comm.1984, 7, 9, 542-544.